● CE conformity.
● Measuring Range: -100kPa…0kPa~100kPa…70MPa.
● Small Size:φ12.6mm, lower package cost.
● Provide OEM, flexible customization.
● Isolated structure, for a variety of fluid medium pressure measurement.
● Industrial process control.
● Gas, liquid pressure measurement.
● Hydraulic system.
● Hydrological monitoring.
● XDB102-6 temperature & pressure dual output pressure sensor can be used in hydraulic system and gas & liquid pressure measurement.
Item | Min. | Typ. | Max. | Units |
Linearity | ±0.15 | ±0.2 | %FS , BFSL | |
Repeatability | ±0.05 | ±0.075 | %FS | |
Hysteresis | ±0.05 | ±0.075 | %FS | |
Zero output | ±2.0 | ±2.0 | mV DC | |
FS output | 45 | 100 | mV DC | |
Temperature output | PT100 Resistance output | |||
Compensated temp. range | 0~70 | C | ||
Working temp. range | -40~ 125 | C | ||
Storage temp. range | -55~ 150 | C | ||
Zero temp. error | ±0.75 | ± 1.0 | %FS @ 25C | |
Full temp. error | ±0.75 | ± 1.0 | %FS@ 25C | |
Long term stability error | ±0.0 | %FS/year | ||
Note: 1. The above performance indicators are tested under the benchmark conditions.
2. The temperature range for temperature drift test is the compensation temperature range. |
Structure condition |
||||
Diaphragm material |
SS 316L |
Housing material |
SS 316L | |
Pin wire |
Gold-plated karaf/100mm silicone rubber wire |
Back pressure tube |
SS 316L (gauge and negative pressure only) | |
Seal ring |
Nitrile rubber | |||
Electrical condition |
||||
Power supply |
1.5 mA DC |
Impedance input |
2.5 kΩ ~ 5 kΩ | |
Impedance output |
2.5 kΩ ~ 5 kΩ |
Response |
(10%~90%) :<1ms | |
Insulation resistance | 100MΩ,100V DC |
Over pressure |
2 times FS | |
Environment condition |
||||
Media applicability |
Fluid that is not corrosive to stainless steel and nitrile rubber |
Shock |
No change at 10gRMS, (20~2000)Hz |
|
Impact |
100g, 11ms |
Position |
Deviate 90° from any direction, zero change ≤ ±0.05%FS |
|
Basic condition |
||||
Environment temperature |
(25±1)℃ |
Humidity |
(50%±10%)RH |
|
Atmospheric pressure |
(86~106) kPa |
Power supply |
(1.5±0.0015) mA DC |
1. To avoid sensor instability, please pay attention to the installation size and installation process to avoid pressing the sensor front within 3 seconds to avoid heat transfer to the sensor.
2. When using a gold-plated cotter pin on a wire, please use a soldering iron below 25W under low temperature soldering.
XDB102-6 |
|
|||||
|
Range code |
Measurement range |
Pressure type |
Range code |
Measurement range |
Pressure type |
0B |
0~20kPa |
G |
12 |
0~2MPa |
G / A |
|
0A |
0~35kPa |
G |
13 |
0~3.5MPa |
G / A |
|
02 |
0~70kPa |
G |
14 |
0~7MPa |
A / S |
|
03 |
0~100kPa |
G / A |
15 |
0~15MPa |
A / S |
|
07 |
0~200kPa |
G / A |
17 |
0~20MPa |
A / S |
|
08 |
0~350kPa |
G / A |
18 |
0~35MPa |
A / S |
|
09 |
0~700kPa |
G / A |
19 |
0~70MPa |
A / S |
|
10 |
0~1Mpa |
G / A |
|
|
|
|
|
Code |
Pressure type |
||||
G |
Gauge pressure |
|||||
A |
Absolute pressure |
|||||
S |
Sealed gauge pressure |
|||||
|
Code |
Electrical connection |
||||
1 |
Gold-plated kovar pin |
|||||
2 |
100mm Silicone rubber leads |
|||||
|
Code |
Other specifications |
||||
Y |
Gauge pressure type can be used to measure negative pressure |
|||||
XDB102-6 -0B-G-1-Y the whole spec |
Order notes
1. To avoid sensor instability, please pay attention to the installation size and installation process to avoid pressing the sensor front within 3 seconds to avoid heat transfer to the sensor.
2. When using a gold-plated cotter pin on a wire, please use a soldering iron below 25W under low temperature soldering.