● CE conformity.
● Range: -100kPa…0kPa~20kPa…3.5MPa.
● Imported chip, Laser trimming.
● Provide OEM, flexible customization.
● φ19mm×5.55mm.
● Industrial process control.
● Gas, liquid and vapor pressure detection.
● Level measurement.
Structure condition |
||||
Diaphragm material |
SS 316L |
Housing material |
SS 316L | |
Pin wire |
Gold-plated karaf/100mm silicone rubber wire |
Back pressure tube |
SS 316L (gauge and negative pressure only) | |
Seal ring |
Nitrile rubber | |||
Electrical condition |
||||
Power supply |
≤2.0 mA DC |
Impedance input |
2.5kΩ ~ 5 kΩ | |
Impedance output |
2.5kΩ ~ 5 kΩ |
Response |
(10%~90%) :<1ms | |
Insulation resistance | 100MΩ,100V DC |
Over pressure |
2 times FS, ( 0C/0B/0A/02 5times FS) | |
Environment condition |
||||
Media applicability |
Fluid that is not corrosive to stainless steel and nitrile rubber |
Shock |
No change at 10gRMS, (20~2000)Hz |
|
Impact |
100g, 11ms |
Position |
Deviate 90° from any direction, zero change ≤ ±0.05%FS |
|
Basic condition |
||||
Environment temperature |
(25±1)℃ |
Humidity |
(50%±10%)RH |
|
Atmospheric pressure |
(86~106) kPa |
Power supply |
(1.5±0.0015) mA DC |
|
All tests are in accordance with relevant national standards, including GB / T2423-2008, GB / T8170-2008, GJB150.17A-2009, etc., and also comply with the Company's "Pressure Sensor Enterprise Standards" provisions of the relevant content. |
1. To avoid sensor instability, please pay attention to the installation size and installation process to avoid pressing the sensor front within 3 seconds to avoid heat transfer to the sensor.
2. When using a gold-plated cotter pin on a wire, please use a soldering iron below 25W under low temperature soldering.
XDB102-3 |
|
|||||
|
Range code |
Measurement range |
Pressure type |
Range code |
Measurement range |
Pressure type |
0B |
0~20kPa |
G |
08 |
0~350kPa |
G / A |
|
0A |
0~35kPa |
G |
09 |
0~700kPa |
G / A |
|
02 |
0~70kPa |
G |
10 |
0~1MPa |
G / A |
|
03 |
0~100kPa |
G / A |
12 |
0~2MPa |
G / A |
|
07 |
0~200kPa |
G / A |
13 |
0~3.5MPa |
G / A |
|
|
Code |
Pressure type |
||||
G |
Gauge pressure |
|||||
A |
Absolute pressure |
|||||
|
Code |
Electrical connection |
||||
1 |
Gold-plated kovar pin |
|||||
2 |
100mm Silicone rubber leads |
|||||
|
Code |
Special measurement |
||||
Y |
Gauge pressure type can be used to measure negative pressure ① |
|||||
XDB102-3 -0B-G-1-Y the whole spec ② |
Order notes
1. To avoid sensor instability, please pay attention to the installation size and installation process to avoid pressing the sensor front within 3 seconds to avoid heat transfer to the sensor.
2. When using a gold-plated cotter pin on a wire, please use a soldering iron below 25W under low temperature soldering.