1. High Accuracy: Precision up to ±0.075% within a 0-40 MPa range.
2. Overpressure Resilience: Withstands up to 60 MPa.
3. Environmental Compensation: Minimizes errors from temperature and pressure changes.
4. Ease of Use: Features a backlit LCD, multiple display options, and quick-access buttons.
5. Corrosion Resistance: Built with materials for harsh conditions.
6. Self-Diagnostics: Ensures reliability through advanced diagnostics.
1. Oil and Petrochemicals: Pipeline and storage tank monitoring.
2. Chemical Industry: Precise liquid level and pressure measurements.
3. Electric Power: High-stability pressure monitoring.
4. Urban Gas: Critical infrastructure pressure and level control.
5. Pulp and Paper: Resistant to chemicals and corrosion.
6. Steel and Metals: High precision in furnace pressure and vacuum measurement.
7. Ceramics: Stability and accuracy in harsh environments.
8. Mechanical Equipment and Shipbuilding: Reliable control in stringent conditions.
Pressure range | -1~400bar | Pressure Type | Gauge pressure and absolute pressure |
Accuracy | ± 0.075%FS | Input voltage | 10.5~45V DC (intrinsic safety explosion-proof 10.5-26V DC) |
Output signal | 4~20mA and Hart | Display | LCD |
Power impact | ± 0.005%FS/1V | Environmental temperature | -40~85℃ |
Housing material | Cast aluminum alloy and stainless steel (optional) |
Sensor type | Monocrystalline silicon |
Diaphragm material | SUS316L, Hastelloy HC-276, Tantalum, gold-plated, Monel, PTFE (optional) | Receiving liquid material | Stainless steel |
Environmental temperature impact |
± 0.095~0.11% URL/10 ℃ | Measurement medium | Gas, steam, liquid |
Medium temperature | -40~85℃by default, up to 1,000℃ with cooling unit | Static pressure effect | ± 0.1%/10MPa |
Stability | ± 0.1%FS/5 years | Ex-proof | Ex(ia) IIC T6 |
Protection class | IP66 | Installation bracket | Carbon steel galvanized and stainless steel (optional) |
Weight | ≈1.27kg |
Model/Item | Specification code | Description |
XDB605 | / | Pressure transmitter |
Output signal | H | 4-20mA, Hart, 2-wire |
Measuring range | R1 | 1~6kpa Range: -6~6kPa Overload limit: 2MPa |
R2 | 10~40kPa Range: -40~40kPa Overload limit: 7MPa | |
R3 | 10~100KPa, Range: -100~100kPa Overload limit: 7MPa | |
R4 | 10~400KPa, Range: -100~400kPa Overload limit: 7MPa | |
R5 | 0.1kpa-4MPa, Range: -0.1-4MPa Overload limit: 7MPa | |
R6 | 1kpa~40Mpa Range: 0~40MPa Overload limit: 60MPa | |
Housing material | W1 | Cast aluminum alloy |
W2 | Stainless steel | |
Receiving liquid material | SS | Diaphragm: SUS316L, Other receiving liquid materials: stainless steel |
HC | Diaphragm: Hastelloy HC-276 Other liquid contact materials: stainless steel | |
TA | Diaphragm: Tantalum Other Liquid Contact Materials: Stainless Steel | |
GD | Diaphragm: gold-plated, other liquid contact materials: stainless steel | |
MD | Diaphragm: Monel Other liquid contact materials: stainless steel | |
PTFE | Diaphragm: PTFE coating Other liquid contact materials: stainless steel | |
Process connection | M20 | M20*1.5 male |
C2 | 1/2 NPT female | |
C21 | 1/2 NPT female | |
G1 | G1/2 male | |
Electrical connection | M20F | M20*1.5 female with a blind plug and an electrical connector |
N12F | 1/2 NPT female with a blind plug and an electrical connector | |
Display | M | LCD display with buttons |
L | LCD display without buttons | |
N | NONE | |
2-inch pipe installation bracket |
H | Bracket |
N | NONE | |
Bracket material | Q | Carbon steel galvanized |
S | Stainless steel |